Quantum Design ATL Helium Liquefiers

Automated 160 Litre Capacity Helium Liquefiers

Quantum Design’s Advanced Technology Liquefiers (ATL) and innovative Helium Recovery, Storage & Purification Systems allow you to recover and liquefy the helium gas currently being lost from the normal boil off and helium transfers of your cryogenic instruments. A perfect solution for research or medical cryostats, Quantum Design’s helium liquefiers and recovery systems allow you to break your dependence on suppliers and no longer be subject to higher costs and diminished supply.

FEATURES

  • Easy-to-use, fully automated operation
  • Portable liquefiers for easy transfers
  • High liquefaction rates up to 30+ litres per day
  • Self-cleaning, uninterrupted service
  • Modular design: your system can grow as your Helium needs evolve
  • Versions available for Direct, Medium and High Pressure Recovery

 

David Want

Product Specialist
tel:+44 (0)1372 378822
david@qd-uki.co.uk

Dr Shayz Ikram

Product Specialist
tel:+44 (0)1372 378822
shayz@qd-uki.co.uk

MODELS

OPTIONS

Quantum Design’s Direct Recovery System is the most simple recovery system to use in order to gain the benefits of the ATL160 liquefiers. Either liquefier model can be used with customer instrument to reclaim helium lost through normal boil off.

THE DIRECT RECOVERY SYSTEM CONSISTS OF THE FOLLOWING COMPONENTS:

  • X – Customer Instrument
  • A – Base ATL160
  • B – Compressor for ATL160
  • C – Back Pressure Controller
  • D – ATL160 Power Distribution Unit

More information available at http://www.qdusa.com/products/helium-liquefiers.html

Quantum Design’s Recovery System with Medium Pressure Storage allows recovery, storage and purification of helium from normal and transfer boil off.  This recovery system is perfect for customers with 1 or 2 cryogenic instruments who want to recover almost all of the helium normally lost through normal operation and cryogenic transfers.

THE RECOVERY SYSTEM WITH MEDIUM PRESSURE STORAGE CONSISTS OF THE FOLLOWING COMPONENTS:

  • A – Base ATL160/160+  Liquefier
  • B – Compressor for ATL160/160+
  • C – AT Recovery Hub – MP
  • D – LN2 Helium Purifier
  • E – Medium Pressure Storage Tank (1000 litres)
  • F – Back Pressure Controller
  • X – Customer Instrument

More information available at http://www.qdusa.com/products/helium-liquefiers.html

Quantum Design’s Recovery System with High Pressure Storage allows recovery, storage and purification of helium from normal and transfer boil off.  This recovery system is perfect for customers with multiple cryogenic instruments or large, multi-room laboratories who want to recover almost all of the helium normally lost through normal operation and cryogenic transfers.

THE RECOVERY SYSTEM WITH HIGH PRESSURE STORAGE CONSISTS OF THE FOLLOWING COMPONENTS:

  • A – Base ATL160/160+ Liquefier
  • B – Compressor for ATL160/160+
  • C – ATP30 Purifier
  • D – Compressor for ATP30 Purifier
  • E – Helium Gas Bag and Controller
  • F – High Pressure Recovery Compressor
  • G – High Pressure Helium Gas Cylinders
  • H – Back Pressure Controller
  • X – Customer Instrument

More information available at http://www.qdusa.com/products/helium-liquefiers.html

  • Purifies 30 litres of helium gas per minute*
  • Purifies helium gas to 99.9995% (better than UHP)
  • Fail Safe Operation – Stops operation before “dirty” gas passes through system
  • Full regeneration of system only takes 5 hours (with no filters or cartridges to replace)*
  • Regeneration easily accomplished through automated software
  • Ensures highest liquefaction rates possible
  • Hydrogen removal option protects instruments from plugging

System Dimensions (L x W x H):
78 x 63 x 160 cm (purifier without compressor)

Compressor Package Model:
Split Air-Cooled, Water-Cooled or Indoor Air-Cooled

Typical Power Consumption and Voltage Range:
5.0 KW; High & Low Voltage Available

*Purifier operation varies based on input helium quality.

  • Includes insert, dewar, heater, hoist, regeneration stand and drier
  • Provides economic purification solution for medium pressure and direct recovery systems
  • Output Purity: >99.999%
  • Helium Inlet Purity: ≤1% Impurities
  • Flow Rate: 0-50 SLPM
  • Hold Time: 2 weeks*
  • LN2 Capacity: 120 Litres
  • LN2 Consumption: 30 litres per week*
  • Regeneration Time: 12 hours
  • Regeneration Interval: 2 months with 0.2% impurities*

*With 10 SLPM of helium flow.

Quantum Design’s Recovery System with Medium Pressure Storage allows recovery, storage and purification of helium from normal and transfer boil off.  This recovery system is perfect for customers with 1 or 2 cryogenic instruments who want to recover almost all of the helium normally lost through normal operation and cryogenic transfers.

THE RECOVERY SYSTEM WITH MEDIUM PRESSURE STORAGE CONSISTS OF THE FOLLOWING COMPONENTS:

  • A – Base ATL160/160+  Liquefier
  • B – Compressor for ATL160/160+
  • C – AT Recovery Hub – MP
  • D – LN2 Helium Purifier
  • E – Medium Pressure Storage Tank (1000 litres)
  • F – Back Pressure Controller
  • X – Customer Instrument

More information available at http://www.qdusa.com/products/helium-liquefiers.html

Quantum Design’s Recovery System with High Pressure Storage allows recovery, storage and purification of helium from normal and transfer boil off.  This recovery system is perfect for customers with multiple cryogenic instruments or large, multi-room laboratories who want to recover almost all of the helium normally lost through normal operation and cryogenic transfers.

THE RECOVERY SYSTEM WITH HIGH PRESSURE STORAGE CONSISTS OF THE FOLLOWING COMPONENTS:

  • A – Base ATL160/160+ Liquefier
  • B – Compressor for ATL160/160+
  • C – ATP30 Purifier
  • D – Compressor for ATP30 Purifier
  • E – Helium Gas Bag and Controller
  • F – High Pressure Recovery Compressor
  • G – High Pressure Helium Gas Cylinders
  • H – Back Pressure Controller
  • X – Customer Instrument

More information available at http://www.qdusa.com/products/helium-liquefiers.html

  • Purifies 30 litres of helium gas per minute*
  • Purifies helium gas to 99.9995% (better than UHP)
  • Fail Safe Operation – Stops operation before “dirty” gas passes through system
  • Full regeneration of system only takes 5 hours (with no filters or cartridges to replace)*
  • Regeneration easily accomplished through automated software
  • Ensures highest liquefaction rates possible
  • Hydrogen removal option protects instruments from plugging

System Dimensions (L x W x H):
78 x 63 x 160 cm (purifier without compressor)

Compressor Package Model:
Split Air-Cooled, Water-Cooled or Indoor Air-Cooled

Typical Power Consumption and Voltage Range:
5.0 KW; High & Low Voltage Available

*Purifier operation varies based on input helium quality.

  • Includes insert, dewar, heater, hoist, regeneration stand and drier
  • Provides economic purification solution for medium pressure and direct recovery systems
  • Output Purity: >99.999%
  • Helium Inlet Purity: ≤1% Impurities
  • Flow Rate: 0-50 SLPM
  • Hold Time: 2 weeks*
  • LN2 Capacity: 120 Litres
  • LN2 Consumption: 30 litres per week*
  • Regeneration Time: 12 hours
  • Regeneration Interval: 2 months with 0.2% impurities*

*With 10 SLPM of helium flow.

Quantum Design’s Recovery System with High Pressure Storage allows recovery, storage and purification of helium from normal and transfer boil off.  This recovery system is perfect for customers with multiple cryogenic instruments or large, multi-room laboratories who want to recover almost all of the helium normally lost through normal operation and cryogenic transfers.

THE RECOVERY SYSTEM WITH HIGH PRESSURE STORAGE CONSISTS OF THE FOLLOWING COMPONENTS:

  • A – Base ATL160/160+ Liquefier
  • B – Compressor for ATL160/160+
  • C – ATP30 Purifier
  • D – Compressor for ATP30 Purifier
  • E – Helium Gas Bag and Controller
  • F – High Pressure Recovery Compressor
  • G – High Pressure Helium Gas Cylinders
  • H – Back Pressure Controller
  • X – Customer Instrument

More information available at http://www.qdusa.com/products/helium-liquefiers.html

  • Purifies 30 litres of helium gas per minute*
  • Purifies helium gas to 99.9995% (better than UHP)
  • Fail Safe Operation – Stops operation before “dirty” gas passes through system
  • Full regeneration of system only takes 5 hours (with no filters or cartridges to replace)*
  • Regeneration easily accomplished through automated software
  • Ensures highest liquefaction rates possible
  • Hydrogen removal option protects instruments from plugging

System Dimensions (L x W x H):
78 x 63 x 160 cm (purifier without compressor)

Compressor Package Model:
Split Air-Cooled, Water-Cooled or Indoor Air-Cooled

Typical Power Consumption and Voltage Range:
5.0 KW; High & Low Voltage Available

*Purifier operation varies based on input helium quality.

  • Includes insert, dewar, heater, hoist, regeneration stand and drier
  • Provides economic purification solution for medium pressure and direct recovery systems
  • Output Purity: >99.999%
  • Helium Inlet Purity: ≤1% Impurities
  • Flow Rate: 0-50 SLPM
  • Hold Time: 2 weeks*
  • LN2 Capacity: 120 Litres
  • LN2 Consumption: 30 litres per week*
  • Regeneration Time: 12 hours
  • Regeneration Interval: 2 months with 0.2% impurities*

*With 10 SLPM of helium flow.

Videos

Downloads

Supplier Info

For even more information, why not visit our suppliers website.

Visit website

Follow us:

 

Keep up to date with our latest product news and developments. Join our mailing list

Top