Label-free Holographic Microscopy

Tomocube

3D Label-free Holographic Microscopy

TomoCube’s HT Series is a ground breaking new high-speed, best in class microscope designed to let researchers view live cells using holographic microtomography technology. One of the world’s first microscopes of its kind, the TomoCube HT Series delivers non-invasive, real-time quantitative data with the highest resolution on the market today.

HT-1 Label-free holographic high resolution imaging for cell biology. Quantitative label-free high resolution live imaging is an exciting new technology that negates the need for using fluorescent markers in your sample. Using refractive index to segment desired objects in your cell, you can rapidly acquire morphological, chemical and mechanical data in 3D.

HT-2 is the world’s first microscope combining both holotomography and 3D fluorescence imaging in one unit. The benefits of using low laser power for holotomography imaging with intermittent fluorescent imaging allows the benefits of low-dose in combination with the specificity of fluorescent labelling. Fluorescent labels can also be used as a standard control to confirm that the holotomography is in agreement with labelling that is more familiar. The HT-2 is also an excellent fluorescent microscope without holotomography and can be used in conjunction with the Tomostudio deconvolution software to give you excellent wide-field fluorescent images.

SPECIFICATION OVERVIEW

  • FEATURES:
  • No labelling or staining required
  • Standard resolution: 166 nm XY, 1 μm  Z
  • High resolution: 110 nm XY, 356 nm Z
  • Fast imaging: 150 fps (2D) 2.5 fps (3D)
  • Non-invasive live cell – image for 72 hours
  • Field of view 80 μm, Depth of field 40μm
  • Correlative Fluorescence available for both standard and high resolution
  • TomoStudio analysis software provided with the instrument - click here to find out more
  • Contact: Dr Shayz Ikram
    Product Specialist

    +44 (0)1372 378822
    shayz@qd-uki.co.uk

    Models

    HT-1

    No labelling or staining required

    Two models;

    HT-1S: Standard resolution: 166 nm XY, 1 μm  Z

    HT-1H: High resolution: 110 nm XY, 356 nm Z

    Fast imaging: 150 fps (2D) 2.5 fps (3D)

    Non-invasive live cell – image for 72 hours

    Field of view 80 μm, Depth of field 40μm

    TomoStudio analysis software provided with the instrument - click here to find out more

    TomoStudio™, Software platform for 2D/3D/4D image analysis

    TomoStudio™, HT-1 operating SW, controls the system and visualises the captured image in various ways. This flexible user interface provides fast imaging capability and 2D/3D/4D visualisation of the cellular image based on 3D RI distributions of the cells and tissues.

    Smart technology for holotomography

    HT-1 use holotomography technology which measures the 3D and 4D refractive index (RI) tomograms. This new technology enables quantitative, label-free measurements of live, unstained cells and tissue samples. With the dynamic micromirror device (DMD), TomoCube have eliminated moving parts from light path while image-capturing and have added unprecedented stability and precision on the outstanding performance of the product.

    HT-2 Fluorescent

    Research and diagnosis in the life sciences depends on the information that can be found using cellular analysis. However, current microscopy techniques limit the quantity and quality of information available to researchers and clinicians

    HT-2 is the world’s first microscope combining both holotomography and 3D fluorescence imaging in one unit. The benefits of using low laser power for holotomography imagine with intermittent fluorescent imaging allows the benefits of low-dose in combination with the specificity of fluorescent labelling. Fluorescent labels can also be used as a standard control to confirm that the holotomography is in agreement with labelling that is more familiar. The HT-2 is also an excellent fluorescent microscope without holotomography and can be used in conjunction with the Tomostudio deconvolution software to give you excellent wide-field fluorescent images.

    Two models;

    HT-2S: Standard resolution: 166 nm XY, 1 μm  Z

    HT-2H: High resolution: 110 nm XY, 356 nm Z

    Fast imaging: 150 fps (2D) 2.5 fps (3D)

    Non-invasive live cell – image for 72 hours

    Field of view 80 μm, Depth of field 40μm

    Correlative Fluorescence

    TomoStudio analysis software provided with the instrument - click here to find out more

    TOMOSTUDIO™, SOFTWARE PLATFORM FOR 2D/3D/4D IMAGE ANALYSIS

    TomoStudio™, HT-2 operating SW, controls the system and visualises the captured image in various ways. This flexible user interface provides fast imaging capability and 2D/3D/4D visualisation of the cellular image based on 3D RI distributions of the cells and tissues.

    SMART TECHNOLOGY FOR HOLOTOMOGRAPHY

    HT-2 use holotomography technology which measures the 3D and 4D refractive index (RI) tomograms. This new technology enables quantitative, label-free measurements of live, unstained cells and tissue samples. With the dynamic micromirror device (DMD), TomoCube have eliminated moving parts from light path while image-capturing and have added unprecedented stability and precision on the outstanding performance of the product.