PRODUCT CONTACT:

David Want
Product Specialist
+44 (0)1372 378822

cryogenics and optical cryostats





Quantum Design Helium Liquefiers

Automated 160 Litre Capacity Helium Liquefiers

Quantum Design Helium Liquefiers

Quantum Design's Advanced Technology Liquefiers (ATL) along with its innovative Helium Recovery, Storage & Purification Systems allow you to recover and liquefy the helium gas currently being lost from the normal boil off and helium transfers of your cryogenic instruments.

Note:  ATL80 not available within the UK & Ireland.

Contact: David Want
Product Specialist
+44 (0)1372 378822
david@qd-uki.co.uk

Contact: Shayz Ikram
Product Specialist
+44 (0)1372 378822
shayz@qd-uki.co.uk

SPECIFICATION OVERVIEW

  • FEATURES:
  • Easy-to-use, fully automated operation
  • Portable liquefiers for easy transfers
  • High liquefaction rates up to 30+ litres per day
  • Self-cleaning, uninterrupted service
  • Modular design: your system can grow as your Helium needs evolve
  • Versions available for Direct, Medium and High Pressure Recovery
  • Options

    ATL160/160+ Direct Recovery System

    Quantum Design's Direct Recovery System is the most simple recovery system to use in order to gain the benefits of the ATL160/160+ liquefiers. Either liquefier model can be used with customer instrument to reclaim helium lost through normal boil off.

    The Direct Recovery System consists of the following components:

    X - Customer Instrument

    A - Base ATL160/160+ Liquefier

    B - Compressor for ATL160/160+

    C - Back Pressure Controller

    D - ATL160/160+ Power Distribution Unit

     

    Specification:

    ATL160/160+

    Average Liquefaction Rate:

    ATL160:    22 – 27 litres/day (0.92 – 1.13 litres/hr)*

    ATL160+:    30+ litres/day (1.25 litres/hr)*

    Dewar Capacity: 160 litres

    System Dimensions (L x W x H):  104 x 76 x 151 cm (liquefier without compressor)

    Compressor Package Model: Split Air-Cooled or Water-Cooled

    Typical Power Consumption and Voltage Range: 6.5 - 7.5 KW; High & Low Voltage Available

    Gaseous Helium Requirement:

    ATL160:    Flow Rate: 0 - 25 SLPM (0 - 0.88 SCFM); Ultra High Purity He (99.999%); 0-10 psi

    ATL160+:    Flow Rate: 0 - 25 SLPM (0 - 0.88 SCFM); Ultra High Purity He (99.999% pure); 1-20 psi

    Fully Automated Touch Panel Control

     

    More information available at http://www.qdusa.com/products/helium-liquefiers.html

    Recovery System with Medium Pressure Storage

    Quantum Design's Recovery System with Medium Pressure Storage allows recovery, storage and purification of helium from normal and transfer boil off.  This recovery system is perfect for customers with 1 or 2 cryogenic instruments who want to recovery almost all of the helium normally lost through normal operation and cryogenic transfers.

    The Recovery System with Medium Pressure Storage consists of the following components:

    A - Base ATL160/160+  Liquefier

    B - Compressor for ATL160/160+

    C - AT Recovery Hub – MP

    D - LN2 Helium Purifier

    E - Medium Pressure Storage Tank (1000 litres)

    F - Back Pressure Controller

    X - Customer Instrument

     

    More information available at http://www.qdusa.com/products/helium-liquefiers.html

    Recovery System with High Pressure Storage

    Quantum Design's Recovery System with High Pressure Storage allows recovery, storage and purification of helium from normal and transfer boil off.  This recovery system is perfect for customers with multiple cryogenic instruments or large, multi-room laboratories who want to recovery almost all of the helium normally lost through normal operation and cryogenic transfers.

     

    The Recovery System with High Pressure Storage consists of the following components:

    A - Base ATL160/160+ Liquefier

    B - Compressor for ATL160/160+

    C - ATP30 Purifier

    D - Compressor for ATP30 Purifier

    E - Helium Gas Bag and Controller

    F - High Pressure Recovery Compressor

    G - High Pressure Helium Gas Cylinders

    H - Back Pressure Controller

    X - Customer Instrument

     

    More information available at http://www.qdusa.com/products/helium-liquefiers.html

    ATP30

    Purifies 30 litres of helium gas per minute*

    Purifies helium gas to 99.9995% (better than UHP)

    Fail Safe Operation – Stops operation before "dirty" gas passes through system

    Full regeneration of system only takes 5 hours (with no filters or cartridges to replace)*

    Regeneration easily accomplished through automated software

    Ensures highest liquefaction rates possible

    Hydrogen removal option protects instruments from plugging

    System Dimensions (L x W x H): 78 x 63 x 160 cm (purifier without compressor)

    Compressor Package Model: Split Air-Cooled, Water-Cooled or Indoor Air-Cooled

    Typical Power Consumption and Voltage Range: 5.0 KW; High & Low Voltage Available

    Purifier operation varies based on input helium quality.

    Supplier info:

    For even more information, why not visit our suppliers website.

    VISIT SUPPLIER

    MEDIA:

    Quantum Design's Advanced Technology Liquefier ATL160

    MEDIA:

    How to insert and remove a transfer line from an ATL

    DOWNLOADS:

    © Quantum Design UK and Ireland Ltd 2018 - Website designed by Treefrog Design
    Top